Free tools

HVAC tools

A ductulator, duct sizing, ventilation, rooftop unit, exhaust and makeup air calculators for contractors, installers and facility managers. Free to use, no sign-up.

Units:

Ductulator: equivalent duct sizes

Enter the duct on your drawings and get the round, rectangular, square and flat oval sizes with the same friction loss per 100 ft. Handy when a duct won't fit in the field and you need to change its shape.

Duct on the drawings

Equivalent rectangular and square sizes

Equivalent flat oval sizes

Need ductwork designed, fabricated or installed?

Get a quote

Duct sizing

Size a duct from airflow and either a friction rate or a target velocity. Typical low-pressure supply ducts are sized at about 0.08 to 0.10 in. w.c. per 100 ft.

Rectangular options for the selected round size

Need a duct system designed or installed?

Get a quote

Friction & static pressure drop

Work out the static pressure lost along a duct run, including the elbows and branch fittings along the way.

Duct

Fittings

Fitting losses use typical loss coefficients (smooth radius elbow 0.15, mitred with vanes 0.25, mitred without vanes 1.2, branch 0.5) multiplied by velocity pressure. Use manufacturer data for dampers, coils, filters and grilles.

Fighting a high-static system? We can test, balance and fix it.

Get a quote

Ventilation rates by space type

Estimate the outdoor air a space needs from its floor area and occupancy, using the ventilation rate procedure (people rate plus area rate).

Typical rates for estimating, based on the ventilation rate procedure. Final design must follow the code and standard that applies to your project. Hospitals and healthcare spaces in BC follow CSA Z317.2. Ask us.

Need ventilation designed or upgraded?

Get a quote

Makeup air heating

Outdoor air brought into a building has to be heated to the supply temperature. Pick your town for its winter design temperature and get the heating capacity, burner input and electric load.

Sensible heat: BTU/h = 1.08 × CFM × ΔT (°F), or kW = 1.2 × L/s × ΔT (°C) ÷ 1000. Design temperatures are approximate January 2.5% values from the BC Building Code climate tables. Confirm them for your project.

Need a makeup air unit supplied, installed or replaced?

Get a quote

Rooftop unit sizing (rough)

A ballpark cooling size for budgeting and early planning, based on floor area and building type. It is not a load calculation. A proper load calc is done before any equipment is selected.

Replacing a rooftop unit? We do like-for-like and upgrade replacements.

Get a quote

Exhaust fan sizing

Exhaust airflow for washrooms, janitor and garbage rooms, parkades and more, by code-style exhaust rate or air changes per hour.

Rates are typical values for estimating. Confirm against the BC Building Code, the BC Plumbing Code and the ventilation standard that applies to your project.

Need exhaust fans replaced, rebuilt or added?

Get a quote

Equipment age check

How far through its typical service life is your HVAC equipment? Plan replacements before they become emergencies.

Typical service lives are median values from ASHRAE equipment-life data. Actual life depends on maintenance, run hours and environment.

Want a professional assessment of your equipment?

Book an assessment

Filter change schedule

Get a filter change interval for your equipment and download the reminders to your calendar.

Best practice is to change filters when their pressure drop reaches the manufacturer's final resistance, often about double the clean drop. A schedule is a good fallback when you don't have a gauge.

Want filters and preventive maintenance taken care of?

Get a quote

These tools give estimates for planning and field use only. Results are not an engineered design. Always follow the drawings, specifications, manufacturer data and the codes and standards that apply to your project. Groen Environmental Systems Inc. accepts no liability for decisions made from these results.